Dual Glossary
The same word can mean different things in clinical practice and machine learning. This glossary pairs a concise definition with the distinction most likely to affect an imaging AI project.
Clinical and imaging terms for engineers
| Term | Meaning and practical distinction |
|---|---|
| Screening | Assessment of a defined population without a specific presenting symptom; prevalence and follow-up differ from diagnostic cohorts. |
| Diagnostic examination | Imaging directed at a clinical question, symptom, or prior finding; not interchangeable with screening. |
| Indication | The clinical reason for an examination, or the specified authorized use of a device; identify which meaning is intended. |
| Finding | An observation such as an opacity or lesion; it is not necessarily a diagnosis. |
| Differential diagnosis | Plausible explanations for findings in context, not a list of independently established diseases. |
| Reference standard | The method used to establish the evaluation target; it may combine expert review, pathology, follow-up, or other evidence. |
| Incidental finding | An observation outside the original examination question; it still needs an appropriate review and follow-up pathway. |
| Triage | Prioritization of attention or workflow; a negative triage result does not automatically rule out disease. |
| Recall | A request for additional assessment after screening; not synonymous with a cancer diagnosis. |
| Lesion | A localized abnormality; its definition and boundaries depend on the task. |
| Longitudinal | Across time for the same person or target; requires correct identity, timing, and comparability. |
| Acquisition protocol | The settings and sequence of measurements used to obtain an examination. |
| Series | A grouping of DICOM objects; one study may contain many series with different roles. |
| Reconstruction | Producing an image from measured signals; distinct from generating a report or classifying disease. |
| Windowing | Mapping an intensity range to display brightness; generally not a change to the underlying measurement. |
| Voxel | A sample in a volumetric grid; its physical dimensions may differ along each axis. |
| Registration | Estimating spatial correspondence between images; registration error can masquerade as biological change. |
| Partial-volume effect | Mixing of contributions within limited spatial resolution, affecting boundaries and measurements. |
| Contrast phase | Timing of acquisition relative to contrast administration; different phases are different model inputs. |
| Hounsfield unit | CT attenuation scale relative to water; not a universal scale for all tomographic imaging. |
| SUV | A normalized PET uptake measure with a specified convention, units, and timing assumptions. |
| Ejection fraction | Fraction of end-diastolic ventricular volume ejected; the arithmetic depends on valid source measurements. |
| Whole-slide image | A digitized tissue section, often a multiresolution pyramid; it is not the complete specimen or case. |
| Grading | Categorizing severity or morphology under a defined system; integer labels may not be comparable across systems. |
| Ungradable | Inadequate for the specified assessment; it must not be relabeled as normal. |
| PACS / RIS / LIS | Picture archive, radiology information system, and laboratory information system; their identities and workflow roles must be integrated. |
Machine-learning terms for clinicians
| Term | Meaning and practical distinction |
|---|---|
| Training / validation / test | Data used to fit a model, select its settings, and estimate held-out performance; repeated tuning on the test set undermines independence. |
| Data leakage | Information unavailable at the intended decision point enters development or evaluation, inflating apparent performance. |
| Domain shift | A change in the input or clinical setting between development and use, such as a different scanner or population. |
| Distribution drift | A change over deployment time; it is a signal for investigation, not automatically proof of clinical harm. |
| Classification | Assigning a category or score to an input; it does not necessarily localize the evidence. |
| Detection | Identifying candidate locations or events; a box is not a precise boundary or histological diagnosis. |
| Segmentation | Assigning labels to pixels or voxels; labels require anatomical and coordinate definitions. |
| Regression | Predicting a numerical quantity; correlation with a reference does not guarantee agreement. |
| Embedding | A learned numerical representation; dimensions are not usually directly interpretable clinical measurements. |
| Foundation model | A broadly pretrained model adapted to downstream tasks; breadth of pretraining is not validation for a specific clinical use. |
| Fine-tuning | Updating model parameters for a new task or dataset; it can improve specialization and introduce new failure modes. |
| Checkpoint | A saved parameter state; preprocessing, labels, and dependencies are still needed to reproduce a result. |
| Calibration | Agreement between predicted probabilities and observed frequencies in a defined setting. |
| Discrimination | Ability to rank or separate outcomes; good discrimination does not imply good calibration. |
| Operating point | The selected threshold or policy at which sensitivity, specificity, and workload are evaluated. |
| Sensitivity / specificity | Positive detection among reference positives and negative detection among reference negatives; specify the unit and population. |
| Positive predictive value | Fraction of positive outputs that are reference positive; depends on prevalence and operating point. |
| AUROC | Ranking performance across thresholds; it does not select a clinically acceptable threshold. |
| AUPRC | Area under the precision–recall curve; its interpretation depends strongly on positive prevalence. |
| Dice score | Overlap measure for masks; a high average can conceal missed small lesions or important boundary errors. |
| Uncertainty | Lack of confidence due to data, labels, or model limitations; a score is useful only if its interpretation is validated. |
| Abstention | An explicit refusal to produce a supported result; requires a defined downstream action. |
| Weak supervision | Training labels are indirect or coarse, such as report-mined labels or slide-level labels for tiles. |
| Multiple-instance learning | Learning from groups of instances with a group-level label, common in whole-slide analysis. |
| Explainability | Methods intended to help understand outputs; a heatmap is not automatically a causal explanation. |
| Hallucination | Generated content unsupported by the available evidence; fluent wording does not make it factual. |
| Agent | A system that selects and sequences tools or actions; permissions and stopping conditions are part of its safety. |
| Latency / throughput | Delay for one task versus tasks processed per unit time; optimizing one may worsen the other. |
| Idempotency | Repeating the same request does not create unintended duplicate effects. |
| Provenance | The traceable relationship among source data, transformations, model versions, outputs, and review. |
| Rollback | Returning to a previously controlled version or workflow after a problematic change. |
Words to clarify in every project
Accuracy may refer to a classification metric, measurement agreement, or general correctness. Name the actual endpoint. Validation may mean a development split, technical verification, external clinical evaluation, or an institutional acceptance process. State which one was performed. Approved may mean internal permission or a particular regulatory pathway; do not use it as a generic synonym for model availability. Normal may mean no target finding in an adequate examination, not the absence of every disease.